<LOGO>
FM Transmitter Measurement Report
Created: 2023-07-08 11-29-12
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 60 dBuV RIRE &
Pilot RDS Phase Difference
7.1 kHz 4.1 kHz 57 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
9 kHz 69 kHz 17120 0,0643
Modulation Power
Limit Measuring Tolerance
8,0 dBr 1,0 dBr
MIN AVE MAX % above 9,0 dBr
5,1 dBr 6,26 dBr 7,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 11:29, 8.07.2023
RT
"RIRE & CHANSONS "
AF EON
87.8, 88.7, 94.4, 95.4, 95.5, 96.2, 101.5 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (60 dBuV) Max at: 69 kHz MIN: 9 kHz % above 75 kHz: 0,0643 Acquired: 2023/07/08 11:28:08 Total samples: 17120 Equivalent time: 0:14:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,1 dBr MIN: 5,1 dBr AVE: 6,26 dBr % above 9,0 dBr: 0,0 Last value: 6,9 dBr (2023/07/08 11:28:07) Station: 101.50 MHz, signal: 5/5 (60 dBuV) 11:16 11:18 11:20 11:22 11:24 11:26 11:28 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality